Pachymetry (corneal thickness)

Measures the thickness of the cornea, to interpret the eye pressure and estimate risk.

In short

Pachymetry Explained Plays on YouTube. By pressing play you agree to YouTube's cookies.

Animation and script by Ronald de Crom, ophthalmologist and glaucoma specialist. Narration: synthetic voice.

Pachymetry measures the thickness of the clear front window of the eye, the cornea. It takes a few seconds, with a small probe after numbing drops or with a camera that does not touch the eye.

A thin cornea can make the measured eye pressure look lower than it really is, and is itself a risk factor for glaucoma.

In depth

Methods
Ultrasound pachymetry, or optical methods such as Scheimpflug imaging and anterior segment OCT. Values from different devices are not fully interchangeable.
Interpretation
Average central corneal thickness is around 540–550 µm. Thin corneas tend to underestimate and thick corneas to overestimate applanation IOP; no correction formula is reliable enough for individual use.
Risk
A thin central cornea is an independent risk factor for conversion from ocular hypertension to glaucoma (Ocular Hypertension Treatment Study).